OL2R
Offline-to-running measurement for precise alignment of critical machinery
Measure how machinery shifts between stopped and operating conditions to establish accurate, machine-specific alignment targets. Ideal for equipment that continues to experience high vibration after cold alignment.
Designed for use with the ACOEM NXA Pro alignment system.

PRODUCT OVERVIEW
Precision alignment made simple
OL2R offers a fast, flexible measurement process that can be completed without keeping the display unit connected. Measurements can be paused, saved and resumed later, making it easier to work around operating schedules. By replacing generalized estimates with data from the individual machine, OL2R helps reduce vibration, prevent repeated adjustments and improve long-term equipment reliability.


KEY CAPABILITIES
The OL2R fixtures, combined with the NXA system, provide:
- An express set up without using the display unit
- A function for continuing the measurement or to save for the future
- An express result – the machine’s individual target values
SYSTEM COMPONENTS
OL2R package with case
- 2 pcs of OL2R fixtures, available in mm or in inch
- Allen key 5 mm or 3/16 inch
- 2 pcs of socket cap screws M6 x 650 or UNC 1/4 x 2 inch
- Thread tap M6 or 1/4 inch
- Allen key 2 mm
- Drill 5 mm
- 4 pcs of batteries, SR44 1,5 v

ACCESSORIES

Tablet
An 8-inch Android tablet built to support efficient, uninterrupted fieldwork. Its rugged design, clear display, intuitive interface, and integrated tools make it easy to work accurately and stay productive in demanding environments.

Magnetic Brackets
Designed for installations with limited space where standard chain-mounted V-brackets cannot be used.
TECHNICAL SPECIFICATIONS
OL2R Fixture Kit Specifications
Weight (with case)
5.2 kg
Weight (without case)
3.2 kg
Case dimensions
335 x 270 x 150 mm
Laser Pointer
Class 2 laser
Material
Anodized aluminum
Operating Temperature (point laser)
0°C – +50°C
Storage Temperature (point laser)
-20°C – +70°C